Medical devices recalls
2,678 recalls since January 2025 from Health Canada, FDA, newest first. Last notice 19 Nov 2026.
Page 13 of 54
- Siemens Medical Solutions USA, Inc recalls ARTIS icono ceilingFDAPotential issue with the Display ceiling suspension (DCS Fix XL) that holds the monitor in place. Over time some screws that keep the monitor…
- Carl Zeiss Meditec AG recalls Zeiss Intrabeam Spherical Applicator 1.5 cm REF:304534-6000-557FDASpherical applicators (radiation therapy accessory) failed to meet manufacturing specifications.
- Hotline IV Fluid Warmer System & AccessoriesHealth CanadaPerformance
- DLP Select 3D Arterial Cannula and DLP Elongated One Piece Arterial CannulaeHealth CanadaPerformance - Sterility
- Hybrid Hydrophilic MicroguidewireHealth CanadaPerformance
- Intramedullary Bone Saw Blade AssemblyHealth CanadaSterility
- Urinary Catheter Trays containing Cliniclean Pericare WipesHealth CanadaPerformance
- Aisys, Avance, and Aespire Anesthesia MachinesHealth CanadaPerformance
- RAPIDLab® 348EX SystemHealth CanadaPerformance
- AirSeal Access Port With Blunt Obturator and AirSeal Access Port With Optical ObturatorHealth CanadaPerformance
- Glidesheath Slender® Introducer SheathHealth CanadaPerformance
- WASPLabHealth CanadaPerformance
- LIFECODES LSA Class IIHealth CanadaPerformance
- NephroMax High Pressure Nephrostomy Balloon CatheterHealth CanadaDevice compatibility
- TMJ Solutions Inc recalls TMJ Bilateral ImplantsFDACustom temporomandibular joint implant may have contained incorrect patient-specific components that led to a poor fit of the implant, leading to a…
- Stryker Neurovascular recalls INZONE DETACHMENT SYSTEMFDAEmbolization coil detachment system devices may experience premature battery drain causing devices to: 1) Not power on; 2) Power on with faint…
- Intuitive Surgical, Inc. recalls Da Vinci ASSYFDAOperative components of surgical systems potentially distributed with E-brake retainer pin, so in event of a structural column failure, the E-brake…
- Ventec Life Systems, Inc. recalls VOCSN+Pro packageFDARespiratory system intended to provide continuous/intermittent ventilator support, may have a damaged back-up battery supporting backup alarm…
- SURGIFY MEDICAL OY recalls Surgify HaloFDAPotential for burr breakage, occurring during bi-portal endoscopic spinal surgery (BESS).
- PFM MEDICAL INC. recalls Multi-Snare SetFDAA snare catheter including luer lock, indicated for removal or manipulation of a foreign body in the vascular system, failed to meet the…
- Medtronic Perfusion Systems recalls Octopus Evolution AS Tissue Stabilizer and 2 moreFDADuring the manufacturing process, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was…
- Dexcom, Inc. recalls Brand NameFDACertain lots of Dexcom G7 sensors originally designated as scrap and intended for destruction were stolen during the destruction process. The…
- Abiomed, Inc. recalls Abiomed Impella CP Set with SmartAssist (10th Generation) containin… and 2 moreFDAPotential for thrombus formation during prolonged use of the introducer.
- GE Medical Systems SCS recalls GE Healthcare AW Server 3.2 ext.6.5FDAGE HealthCare has become aware of a context synchronization issue in AW Server 3.2 ext. 6.5. When a user selects a patient or exam in the AW Server…
- Medline Industries, LP recalls Medline Convenience KitsFDAThe Medline Convenience Kits contain Arrow Kits and Sets that include Lidocaine Hydrochloride Injection, USP and Bupivacaine Hydrochloride in…
- Zimmer, Inc. recalls Off-Axis Comprehensive Shoulder System and 2 moreFDAFive complaints have been received identifying issues where the plastic guides were catching during reaming, leading to breakage.
- Medline Industries, LP recalls Convenience kits containing select SKUs of 10mL Polycarbonate Color…FDAFirm identified unapproved design changes to the products outside of the 510(k) cleared by the FDA. Products not initially reported in RES 98601.
- Boston Scientific Corporation recalls Intera Oncology INTERA 3000 Hepatic Artery Infusion PumpFDAThere is the potential for leakage along the drug pathway from the pump through the end of the catheter.
- IPG Medical Corporation recalls Thuvera Laser ConsoleFDASoftware anomaly that causes a false display of error code 5018.
- Zimmer, Inc. recalls Brand NameFDAFirm received a complaint with no clinical impact in which a posterior augment was found within the distal augment package.
- Philips North America Llc recalls Philips Avalon Fetal MonitorFDAMonitor has incorrect assembly of the speaker connector which can cause device cables to be pulled out of the housing and increase the risk of…
- Acumed LLC recalls Acumed Hexalob Screw various sizesFDADue to manufacturing error, hexalobe screws used with wrist fixation system may break during use.
- Philips North America Llc recalls Philips Telemetry Monitor 5500 1.4 GHzFDAPotential for device reset to default "NEW_DEVICE" state, which may lead to a to loss of device configuration and the equipment label, resulting in…
- Abiomed Introducer Kits with Impella Heart PumpsHealth CanadaPerformance
- Argon Medical Devices L-Cath™ PICC and Midline CathetersHealth CanadaPerformance
- UHI-4 High Flow Insufflation System - InsufflatorHealth CanadaPerformance
- Infinion™ CX Contact Lead KitHealth CanadaPerformance
- Beta Bionics, Inc. recalls iLet Bionic PancreasFDAThe reason for the recall is: it was found in version 3.3.6 of the iLet ACE Pump firmware and all previous releases that a screen unlock failure…
- Smith & Nephew, Inc. recalls TRIGEN PROXIMAL STRAIGHT HUMERAL NAIL 8/7 X 16FDAHumeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are…
- Steris Corporation recalls HarmonyAIR A-Series Surgical Lighting SystemFDAThere is a potential for paint delamination (chipping/peeling) on the lighting system's light heads.
- Steris Corporation recalls HarmonyAIR A-Series Surgical Lighting System and 1 moreFDAThe the plus and minus buttons (+/-) used to control light intensity on the light heads may detach.
- ARROW INTERNATIONAL, LLC recalls Description/REF and 1 moreFDALidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have…
- Merit Medical Systems, Inc. recalls Splashwire Hydrophilic Guide WireFDADue to unsealed portions of pouches.
- Abiomed, Inc. recalls Automated Impella Controller (AIC)FDAPotential software error in the Automated Impella Controller ("AIC" ) when used in conjunction with left ventricular Impella devices.
- ConMed Corporation recalls ConMed AirSeal 12mm Access Port and Obturator with Blunt Tip and 6 moreFDAPotential for overpressure alerts.
- BD SWITZERLAND SARL recalls BD Connecta" BD Luer-Lok" 360 REF 394910 UDI-DI codeFDADue to stopcock issues when using the plastic luer-lok syringe, the connection at the Port C may over thread or continue to spin rather than…
- Abiomed, Inc. recalls Impella CP Set with SmartAssistFDAExposure to the low purge pressure occurrence may result in persistent low purge pressure alarms and, in some cases, interruption or loss of…
- Medline Industries, LP recalls Medline convenience kits and 6 moreFDAKits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable…
- Accriva Diagnostics, Inc. recalls directCHECK ACT-LR whole blood quality controlFDAAssayed Whole blood control contains labeling with incorrect performance range.
- GE Medical Systems, LLC recalls Giraffe OmniBed Field Replaceable Unit (FRU) and 2 moreFDAGE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain…