Medical devices recalls
2,678 recalls since January 2025 from Health Canada, FDA, newest first. Last notice 19 Nov 2026.
2,678recalls on record
Page 26 of 54
- FDAMedline Industries, LP recalls Medline Hudson RCI Medium Concentration Oxygen MasksFDAFirm received multiple complaints regarding tubing disconnecting from oxygen mask. If issue occurs during use, may lead to delay in patient care and…
- FDAIMRIS Imaging Inc recalls Brand NameFDATorque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision,…
- FDAPhilips North America Llc recalls Philips Smart-hopping 2.0 AP 1.4 GHzFDAIt was found that the MX40 device could not reconnect to the PIC iX when moving between Radiohead and Trident 1.4 GHz access points if the signal…
- FDAApplied Medical Resources Corp recalls Kii Low ProfileFDAThere is the potential for extended length of the blade obturator after assembly into the cannula and seal housing.
- FDASiemens Medical Solutions USA, Inc recalls LUMINOS Lotus MaxFDAA potential issue associated with LUMINOS Lotus Max and Luminos dRF Max systems with software version VF11 with bucky wall stand for mobile…
- FDAVision RT Ltd recalls The AlignRT InBore system contains six Class 1 lasers which enables…FDAVision RT is informing customers of an omission identified in the Instructions for Use for AlignRT InBore systems. Information identifying the…
- FDAPhilips Healthcare (Suzhou) Co., Ltd. recalls Philips Incisive CTFDAPotential for incomplete scan due to unstable connection inside of floating sensor.
- Health CanadaOER-PRO and OER-Elite Endoscope ReprocessorHealth CanadaPerformance
- Health CanadaBS 3/8x3/32 L1.7 (Bubble Sensor for 3/8” X 3/32” tubing, length 1,7 m)Health CanadaPerformance
- FDAVortex Surgical Inc. recalls Vortex Surgical 25ga Illuminated Flex-Tip Laser ProbeFDAReason for the voluntary recall is some products in this lot are not passing through a 25ga cannula smoothly.
- FDAFerndale Laboratories, Inc. recalls Brand NameFDAButyrate tube cracks during actuation, rendering product unusable.
- FDASheathing Technologies Inc recalls Sheathes3D Seamless Viral BarrierFDAVaginal/rectal ultrasound probe covers with a viral barrier may have product defects, which may result in contamination during use, posing an…
- FDABeaver-Visitec International, Inc. recalls BVI Leos Laser and Endoscopy SystemFDAManufacturing deviation in which the ferrites specified for the USB cable assembly linking the Nurse Monitor touchscreen to the System Controller…
- FDAPhilips Ultrasound, LLC recalls Philips EPIQ Ultrasound Systems (various models) used in conjunctio…FDARetroactive: Ultrasound may experience an unexpected automatic reboot, resulting in damage to transducer.
- FDASHENZHEN ATOMSTACK TECHNOLOGIES recalls Material Processing Laser ProductsFDALack of Remote Interlock Connector - required per 21 CFR 1040.10(f)(3)
- Health CanadaOlympus Medical Single Use Electrosurgical KnivesHealth CanadaDevice compatibility
- Health CanadaOlympus Single Use Electrosurgical KnivesHealth CanadaDevice compatibility
- Health CanadaJumper Medical Fetal DopplerHealth CanadaLabelling and packaging
- Health CanadaAllura Xper and Allura CV20 SystemsHealth CanadaPerformance
- Health CanadaCardinal Health™ Chest Drain Units and AccessoriesHealth CanadaLabelling and packaging
- Health CanadaEcono Sterile™ instrumentsHealth CanadaSterility
- Health CanadaThunderbeat Hand InstrumentsHealth CanadaPerformance
- Health CanadaShockPulse Lithotripsy System, Generator and TransducerHealth CanadaPerformance
- Health CanadaPatient Information Center IXHealth CanadaDevice compatibility
- FDACareFusion 303, Inc. recalls BD Pyxis MedStation ESFDAAutomated Dispensing Cabinets (ADC) received a Half Height CUBIE drawer firmware update, which caused a Cubie Insert event which prompts software to…
- FDABeckman Coulter Ireland, Inc. recalls BECKMAN COULTER BICARBONATE REFFDABicarbonate reagent may generate falsely high Bicarbonate results due to interference with Lactate Dehydrogenase (LDH) in the test sample.
- FDAHowmedica Osteonics Corp. recalls The Stryker CranialMask Tracker is a single-use device consisting o…FDAWhen the device is activated during surgery, the device software issues an error message "Instrument Face Mask (6001385000000) is not valid for this…
- FDADiasol, Inc recalls Brand NameFDASafety and efficacy of dialysis acid concentrate cannot be assured
- FDAICU Medical, Inc. recalls LifeShield Drug Library Management (DLM)FDAFor certain customers, the Change Summary review option ceases to operate as expected for any migrated library after the migration has been…
- FDADraeger, Inc. recalls Draeger Vapor 2000 and 1 moreFDAA certain component of affected devices was not delivered within specification and contained impurities.
- FDAICU Medical, Inc. recalls LifeShield Drug Library Management (DLM)FDASoftware issue only allows Concentration Limits to be defined to one digit of precision past the decimal point (0.1) instead of three digits…
- FDACook Incorporated recalls Flexor Check-Flo Introducers and Sets and 2 moreFDACook Medical identified that products supplied in the affected device lots may have been manufactured out of specification. Impacted products may…
- FDAMedtronic Neuromodulation recalls Restore Clinician Programmer Application (CP App)FDASoftware issue where a Device Reset message displayed on the app was unable to be cleared. In rare cases, this resulted in an inability to resume…
- FDAIntuitive Surgical, Inc. recalls da Vinci 5FDASurgical system Error 23062 due to connector1) Partially damaged "Potential problem with ergonomics: Disable - Retry " or 2) Failed "Disable…
- FDAAlcon Research LLC recalls Brand NameFDAOphthalmic procedure packs may have incomplete seals affecting sterility.
- FDAZimmer, Inc. recalls Brand NameFDAAffected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk…
- FDAMicrobiologics Inc recalls KWIK-STIK 2-Pack and 2 moreFDAAffected units may fail to recover the target microorganism Campylobacter jejuni subsp. jejuni derived from ATCC 29428.
- FDAAGFA Healthcare Corp. recalls Brand nameFDAIt is possible to exceed the maximum allowed Air Kerma rate (AKR) of 88mGy/min for pulsed fluoro exams. This can happen in case the framerate is…
- Health CanadaTEGO ConnectorHealth CanadaPerformance
- Health CanadaCellMek SPSHealth CanadaPerformance
- Health CanadaCodman Microsensor® Basic Kits and CereLink™ ICP Sensor Basic KitsHealth CanadaSterility
- Health CanadaCheckcell®Health CanadaSterility
- Health CanadaMedline Homecare BedsHealth CanadaPerformance
- Health CanadaAzurion R2.1.10 and R2.2.10 systemsHealth CanadaPerformance
- Health CanadaMedline Hudson RCI Medium Concentration Oxygen MasksHealth CanadaPerformance
- FDADSAART LLC recalls Brand NameFDADue to manufactured products that deviated from established specifications and being distributed without obtaining the required FDA premarket…
- FDAMyofunctional Research Company USA recalls Myosa for Kids KS1 REF MyOSAKS1_Sb/Sp/Mb/Mp/Lb/Lc KS2 REF…FDADue to firm mistakenly distributing product within the U.S. without FDA premarket clearance/approval.
- FDAPATH recalls MADSEN ACCUSCREEN TEOAE/DPOAE/ABR Probe (P/N 8-69-41100)FDAFollowing a component change in the DPOAE probe (speaker replacement), technical distortions may occur at high stimulus levels combined with…
- FDAMedtronic MiniMed, Inc. recalls InPen AppFDAWhen app is uninstalled and reinstalled, insulin pen software issue causes Choose Notification Style Screen to not show during setup so users can't…
- FDAFresenius Medical Care Holdings, Inc. recalls X CAREsystem +CLiC +CDX;FDASeveral software anomalies with the potential to impact patient treatment, of which one includes the possibility to result in treatment stop if…