  1. Jewel Precision Sheet Metal & Machining Co, Inc. recalls Jewel Precision Reusable Rigid Sterilization Container SystemFDAThe Instructions for Use do not match the 510(k) FDA cleared indications for use or sterility shelf life.
  2. Jewel Precision Sheet Metal & Machining Co, Inc. recalls Jewel Precision Reusable Rigid Sterilization Container SystemFDAThe 8-inch model of the Jewel Precision Reusable Rigid Sterilization Container System (i.e., model number: JP-24-8) was not cleared by the FDA. The…
  3. MEDLINE INDUSTRIES, LP - Northfield recalls Medline UMBILICAL TRAY W/3.5&5FR CATHFDAThere is a possible packaging defect impacting the outer Tyvec pouch that protects the sterile product.
  4. Integra LifeSciences Corp. (NeuroSciences) recalls MicroMyst ApplicatorFDALack of sterility assurance.
  5. GE Medical Systems China Co., Ltd. recalls GE Healthcare LOGIQ F R3 Ultrasound System and 1 moreFDAGE HealthCare has become aware that the Estimated Fetal Weight (EFW) measurement data feature on the Versana Premier R3 and LOGIQ F R3 series…
  6. RECORDATI RARE DISEASES INC. recalls Caphosol Artificial Saliva (32 doses sachet box)FDAOut of specification stability test result for the Caphosol B solution from process validation lots
  7. Philips North America Llc recalls Spectral CTFDADevices with affected software may experience two unintended motion issues that may lead to contact between the Gantry or table with the operator or…
  8. CareLink SmartSync™ ApplicationsHealth CanadaPerformance
  9. Nellcor™ Bedside SpO2 Patient Monitoring SystemHealth CanadaPerformance
  10. Preat Corp recalls Biomet 3i Certain-compatible 4.1 mm Milled Ti Abutment REF 9001767-…FDADue to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a…
  11. Dexcom, Inc. recalls Dexcom One+ Continuous Glucose Monitoring System and 3 moreFDADefective foam or an assembly error may cause the receiver speaker to lose contact with the printed circuit board, leading to missed audible alerts…
  12. ICU Medical, Inc. recalls ICU Medical Plum Solos and 1 moreFDAInternal testing found that Plum Duo pumps with software version 1.1.1 have a workflow that may result in bypassing the Maximum Dose Limit alert.…
  13. BALT USA, LLC recalls Prestige Coil System REFs/UDI-DI codes and 1 moreFDADue to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification.
  14. Fresenius Medical Care Holdings, Inc. recalls X HDF Hemodialysis Blood Tubing SetFDAPotential of blood leak occurring between the lower port of the venous chamber and the tubing include: hemodiafiltration (HDF), hemodialysis (HD),…
  15. Cook Incorporated recalls Beacon Tip 5.0 Fr Angiographic catheters are designed to facilitate…FDACook Medical identified that catheters supplied in the affected device lots may experience tip separation.
  16. Ohio Medical Corporation recalls GCE HEALTHCARE Zen-O liteFDAErroneous calibration values, potentially resulting in: as the device ages, oxygen purity will gradually decrease to the point where the device…
  17. Guangzhou Pluslife Biotech Co., Ltd. recalls Brand NameFDADevices were distributed in the U.S. market without obtaining the required FDA premarket authorization (e.g., 510(k) clearance or PMA).
  18. HANGZHOU ACOSOUND TECHNOLOGY CO., LTD. recalls AcoSoundFDAThree issues 1. Label error: The manufacturer information in the labeling is not correct, the manufacturer's name is mislabeled as "Developed by…
  19. Orthofix Srl recalls REFFDARetrospective; Their is the potential that implantable intramedullary lengthening nails may bend at the distal tail during insertion resulting in…
  20. Chamberlain Technologies LLC recalls SURGIMESH WN and 1 moreFDAPotential presence of residual adhesive material on the mesh surface.
  21. Diagnostica Stago, Inc. recalls STAFDAPotential for shorter clotting times in clotting tests which have a dilution, leading to possible overestimate of around 1%
  22. Spectral Instruments Inc recalls Ami HTX. and 1 moreFDAThe X-ray safety and manufacturing date labels affixed to the Lago X/ AMI HTX instrument do not correspond exactly to the labeling stipulated by the…
  23. Siemens Medical Solutions USA, Inc recalls UROSKOP Omnia Max and 1 moreFDAA resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire.
  24. Guedel AirwayHealth CanadaPerformance
  25. Dual Flat Panel Monitor (DFPM) Accessory To The HarmonyAIR® A-Series And E-Series Surgical Lighting SystemsHealth CanadaPerformance
  26. Dexcom G7 ReceiverHealth CanadaPerformance
  27. Acuvue® Oasys Max 1-Day Multi-Focal Contact LensesHealth CanadaPerformance
  28. Biotrin Parvovirus B19 IgMHealth CanadaPerformance
  29. Azurion 7 M20Health CanadaPerformance
  30. VersaCross™ Access Solution, TorFlex™ Transseptal Guiding Sheath and VersaCross™ Transseptal SheathHealth CanadaSterility
  31. Uroskop OmniaHealth CanadaPerformance
  32. HeartSine® Samaritan® PadsHealth CanadaPerformance
  33. OptiSite and Fem-Flex II Arterial Perfusion CannulasHealth CanadaPerformance
  34. Estrone RIA kitsHealth CanadaPerformance
  35. Estrone RIA kitsHealth CanadaPerformance
  36. Medtronic, Inc. recalls Azure S DR MRI SureScanFDAIdentified devices may experience sudden battery power failure without alarm, power supply power-on-resets, and interruption of therapy. Potential…
  37. Olympus Corporation of the Americas recalls Brand NameFDAPotential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing…
  38. BD SWITZERLAND SARL recalls BD TEXIUM CLOSED MALE LUER WITH FEMALE CAP and 3 moreFDASterile, single use closed system drug transfer devices, standalone or on infusion sets or bonded syringes, may leak at the interface between the…
  39. Microtek Medical, Inc. recalls Microtek Patient Drape ECOLAB AP6MMN Patient DrapeFDADue to non-sterile products being labeled as sterile
  40. Beckman Coulter, Inc. recalls DxI 9000 Access Immunoassay AnalyzerFDAA new motor/encoder and cable was introduced into instruments manufactured starting with serial number 300141 incorrectly. This incorrect…
  41. Natus Neurology DBA Excel Tech., Ltd. (XLTEK) recalls Brand NameFDAElectrode placement labels on the Digital Acquisition Box (DAB) were applied backwards. This may ultimately lead to misdiagnosis of seizure location…
  42. Covidien recalls Newport HT70 VentilatorFDAVentilator Printed Circuit Board Assembly may have two separate capacitors that may fail, which may result in the ventilator either shutting down…
  43. Zyno Medical LLC recalls Z-800 Infusion System and 3 moreFDAUnreleased software versions were installed on distributed devices without verification or validation.
  44. Copan Italia recalls BD BBL CultureSwab EZ Collection and Transport SystemFDASwabs for specimen collection may be prone to breakage during product usage.
  45. Remel, Inc recalls Thermo SCIENTIFIC Sensititre Cation Adjusted AutoRead Mueller-Hinto…FDAProduct may have an off color affecting perfomance
  46. Baxter Healthcare Corporation recalls Baxter Novum IQ Syringe PumpFDABaxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue…
  47. Baxter Healthcare Corporation recalls .5 V replacement rechargeable batteries for Hillrom WELCH ALLYN Poc…FDAThe replacement rechargeable batteries inserted into the Welch Allyn PocketScope handles have the potential to cause a short circuit in the handle,…
  48. GE Medical Systems Information Technologies Inc recalls MUSE 5 SystemsFDAThe MUSE Administrator Account active directory or local credential could potentially be used from your local network to log into a GE HealthCare…
  49. Mobius Mobility LLC recalls iBOT PMD with software version 01.05.24FDASoftware issue that could potentially lead to the device tipping over from Balance Mode.
  50. American Contract Systems, Inc. recalls LOWER EXTREMITYFDATest results for cast padding component included in procedure trays shows Ethylene Oxide/Ethylene Chlorohydrin (EO/ECH) residuals exceeded residual…